Dt-el-usb-tcv4.cdr:coreldraw

Thermocouple Data Logger with USB Interface This data logger measures and stores over 32,000 temperature readings from either a K, J or T type thermocouple . Athermocouple is attached via the thermocouple socket at the base of the unit. The user can easily set up the thermocouple type, logging rate, start-time, logging mode, and download the stored data by plugging the modulestraight into a PC'sUSB port and running the purpose designed software underWindows 2000, XP or Vista. Data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-lifelithium battery, whichwil last forapproximately 6 months.
•-200 to +1300°C Measurement Range (K-type)•-130 to +900°C Measurement Range (J-type)•-200 to +350°C Measurement Range (T-type) •USB Interface for Set-up and Data Download•2 User-Programmable Alarm Thresholds •Bright Red and Green LED Indication•Replaceable Internal Lithium Battery•Supplied with basic K-type thermocouple rated from 0 to 110°C (32 to 230°F) WINDOWS CONTROL SOFTWARE
Easy to install and use, the control software runs under Windows 2000, XP (Home and Professional Editions) and Vista (32-bit). It allows the user to set up and download any EL-USB-TC. The latest version of the control software may be downloaded from DATA LOGGER SET-UPS
Standard Data Logger (Data Logger, Software on CD, Battery, 1.5m basic K-type Thermocouple) •Logging Rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr)•High and Low Alarms Replacement Battery •Start Date and Start Time •Range of logging modes available Probe Measurement range (K-type) Probe Measurement range (J-type) Probe Measurement range (T-type) Operating temperature range * Resolution (internal and displayed) Accuracy (logger error) 1/2AA 3.6V Lithium Battery Life *** * Using thermocouple sensors, the EL-USB-TC can log temperatures as detailed above, but the data logger should not be subjected to temperatures outside the Operating temperature range.
** EL-USB-TC is designed to be used whilst disconnected from USB port.
*** @ 25°C and 1m logging rate LASCAR ELECTRONICS LTD.
LASCAR ELECTRONICS INC.
LASCAR ELECTRONICS (HK) LIMITED 4258 West 12th Street Unit Nos. 6-8 , 19/F., Futura Plaza 111-113 How Ming Street WILTSHIRE SP5 2SJ Kwun Tong, Kowloon TEL: +44 (1794) 884567 TEL: +1 (814) 835 0621 TEL: +852 2797 3219 FAX: +44 (1794) 884616 FAX: +1 (814) 838 8141 FAX: +852 2343 6187 Specifications liable to change without prior warning
Applies to EL-USB-TC
Thermocouple Data Logger with USB Interface LED FLASHING MODES
- The first LED flashes orange (O) to indicate a problem condition on the EL-USB-TC.
- The second LED flashesgreen or red (G/R) to indicatealarm level status.
Itwillflash red when the loggedtemperature has exceeded a Low orHigh alarm level.
By default latching is enabled, so the red LED will continue to flash even after the logged temperature has returnedto normal. The red LED will effectively have latched into its alarm condition. This feature ensures that the user is notified that an alarm levelhas been exceeded, without the need to download the data from the logger.
Latching can be turned off via the control software. The red LED will then no longer continue to flash after the logged temperaturehas returned to normal. Instead, thegreen LED willflash.
The LEDs onthe EL-USB-TCwill flash in one of the following ways: Green LED flashes twice every 10 seconds
- The data logger is not currently logging, but is primed to start at a later date and time.
Green LED flashes once every 10 seconds
- The most recently logged temperature is between the Low alarm and High alarm levels.
Green and Orange LEDs flash once every 10 seconds
- The most recently logged temperature is between the Low alarm and High alarm levels, but the data logger's memory is full, so no more readings are stored.
NB: If latching is enabled, then a flashing green LED indicates that no alarm condition has ever been logged.
Red LED flashes once every 10 seconds
- The most recently logged temperature is equal to or lower than the Low alarm level.
NB: If latching is enabled, then the alarm condition may have been triggered a while
Red and Orange LEDs flash once every 10 seconds
- The most recently logged temperature is equal to or lower than the Low alarm level,
but the data logger's memory is full, so no more readings are stored.
NB: If latching is enabled, then the alarm condition may have been triggered a while ago.
Red LED flashes twice every 10 seconds
- The most recently logged temperature is equal to or higher than the High alarm level.
NB: If latching is enabled, then the alarm condition may have been triggered a while ago.
Red and Orange LEDs flash twice every 10 seconds
- The most recently logged temperature is equal to or higher than the High alarm level,
but the data logger's memory is full, so no more readings are stored.
NB: If latching is enabled, then the alarm condition may have been triggered a while ago.
Orange LED flashes once every 60 seconds
- The battery is reaching the end of its useful life, as its voltage has dropped below 3.3V.
- Data logging continues until the battery voltage drops below 2.8V.
No LEDs flash
- The logger is not being used.
- The logger was logging, but has now shut down due to a flat battery (voltage has dropped below 2.8V).
Plug the data logger into the PC and run the control software to find out which condition applies.
Specifications liable to change without prior warning
Applies to EL-USB-TC
Thermocouple Data Logger with USB Interface DIMENSIONS All dimensions in mm (inches)
Werecommend that you replacethe battery every 6 months, or priorto logging critical data.
The EL-USB-TC does not lose its stored readings when the battery is flat or when the battery is replaced; the datalogging process will however be stopped and cannot be re-started until the battery has been replaced and the logged datahas been downloaded to PC.
Check with your supplier that the battery you are ordering is 'press fit' and is not fitted with solder tags. Before replacing the battery, remove theEL-USB-TC from the PC.
Leaving the EL-USB-TCplugged into the USBportforlongerthan necessarywill causesome of the battery capacity to be lost.
WARNING: Handle lithium batteries carefully, observewarningson battery casing.
Dispose of in accordancewith local regulations.
Specifications liable to change without prior warning
Applies to EL-USB-TC

Source: http://www.hammerelectronic.dk/images/lascar%20datalogger%20EL-USB-TC.pdf

e-brei.net

+972 (0)52.7116408 Mazal Tov per il 26esimo com- pleanno della moglie di uno degli autori di "Momenti di Torà". Che Hashem la ripaghi per avermi dato la possibilità di scrivere e studiare Torà durante tutto l'anno passato. E che tutti i desideri del suo cuore le siano realizzati, e possa vedere i nostri figli ed i figli dei nostri figli

ucb-cms.krankikom.de

HIGHLIGHTS OF PRESCRIBING INFORMATION Suicidal Behavior and Ideation (5.1) These highlights do not include all the information needed to use Patients should be advised that VIMPAT may cause dizziness VIMPAT® safely and effectively. See full prescribing information and ataxia. (5.2) for VIMPAT.