Strana1_23.cdr


RELATIVE HUMIDITY AND
Food and beverages industry (HACCP)
Pharmaceutical industry

HVAC (heating, ventilation, air conditioning, cooling)
Building and energy management

Research and development, Laboratories (GLP)
Technological processes and warehouses
Museums, archives, galleries

ogger are designed for recording of temperature or temperature together with signal from a contact. Values are stored to a non volatileelectronic memory. Data transfer to the personal computer for furtheranalysis is performed via USB, RS232, GSM or Ethernet interface by Thermometer h grometer means of a proper adapter.
included traceable calibration certificateeasy user ajdjustment and calibration of relative humidity by means of optional accessory and PC softwarevariability of connection to the computer - USB, RS232, Ethernet, GSM modemfast data transfer to the PC (full memory of 32 000 readings for approximately 30s)permanent connection to the PC enabled, data is possible to download even during logginglarge dual line display with special symbols, switchableoptional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LEDtwo alarm modes: instant or with memory (detected alarm is indicated till alarm memory is cleared)robust watertight case, easy installation, locking enabledlow power consumption - battery life up to 7 years, indication of remaining battery life, easy battery replacementstandard temperature sensor is Pt1000combination of measurement of temperature and RH with two user calibrated voltage signals 0-5Valso logging mode enabled, when logging runs only, if measured values are out of adjusted alarm limitseach logger is possible to describe with text of maximum 32 characterseach channel is possible to describe with text of maximum 16 characterspassword protection is enabled to prevent unauthorized manipulation with logger Operating temperature range - models R312x no display: -30 to +80°COperating temperature range - models S3xxx with display: -30 to +70°CAccuracy of temperature measurement - internal Accuracy of the S3631 data logger Pt1000 input without ±0.2°C from -50 to +100°Cprobe: ±0.2% from reading from +100 to +260°C±0.4% from reading from -90 to -50°C Accuracy of relative humidity measurement: ±2.5% RH from 5 to 95% at 23°C Accuracy of dew point temperature ±0.5°C from 30 to 95% RH year, leap year, month, day, hour, minute, second Logging interval: adjustable from 10s to 24h Display and alarm refresh: every 10 s (every minute in low power mode) Total memory capacity: 32000 values in non-cyclic mode Data logging modes: non-cyclic – logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Dimensions without connectors: S3xxx loggers with display 93x64x29mmR312x loggery without display 93x64x26mm Lithium battery 3.6V, size AA Typical battery life in low power mode (1min): 7 years R312x, 6 years S3120, S3121, S3631, S3541 Typical battery life in standard mode (10 second): 3 years R312x, 2.5 years S3120, S3121, S3631, S3541 Battery life in continuous online mode with interval 1 min: reduced to 70% of the above livesBattery life in continuous online mode with interval 10 s: Protection of loggers with internal sensors: IP67, sensors covered with a plastic cover with IP30 protection Protection of loggers S3121, R3121 with probe on the IP67, sensors protected with a stainless steel mesh with IP40 protection. Filtering ability 0,025mm.


RELATIVE HUMIDITY AND
TEMPERATURE LOGGERS

LOGGERS WITH DISPLAY
THERMOMETER-HYGROMETER with internal sensors.
temperature -30 to +70°C Dew point temperature reading.
humidity 0 to 100% THERMOMETER-HYGROMETER including dew point temperature temperature -30 to +105°C* reading. With external T+RH probe on a 1 meter cable. Cable lengths humidity 0 to 100% 2 and 4 meters available optionally.
Probe diameter is 18mm, length 90mm.
THERMOMETER-HYGROMETER with internal T+RH sensors. Additional T+RH internal -30 to +70°C connector for external temperature probe. Alternative display of dew- external -90 to +260°C point temperature, external probe temperature and the temperature humidity 0 to 100% difference of external probe and dew-point temperature.
THERMOMETER-HYGROMETER including dew-point calculation with internal -30 to +70°C internal T+RH sensors. Additional Canon 9 pins connector for two 2 x 0 to 5V humidity 0 to 100% signals 0 to 5Vdc (±0.2% FS accuracy).
Necessary to order connector for connection of input signals.
THERMOMETER-HYGROMETER with internal sensors.
temperature -30 to +80°C Dew point temperature reading.
humidity 0 to 100% THERMOMETER-HYGROMETER including dew point temperature -30 to +105°C* temperature reading. With external T+RH probe on a 1 meter humidity 0 to 100% cable. Cable lengths 2 and 4 meters available optionally.
Probe diameter is 18mm, length 90mm.
* temperatures over +85 with the limitation specified in graph Thermometer hygrometerS3541 with 0 to 5V inputs No accessory is included. For basic use it is necessary to order USB adapter or COM adapter for communication with computer, optionally start/stop magnet, if needed to control logging the other way than directly from computer. Alsoconnector for input signals connection is necessary to order - only for model S3541.
certificate from the manufacturer with declared metrological traceability of etalons is based on
requirements of EN ISO/IEC 17025 standard. Included is also battery. Free program for Windows is ready to download fromwww.cometsystem.cz. Program enables to control all logger functions and viewing and printing of record in numerical and simplegraphic format. It is possible to export logged values to dbf or txt formats for further analysis.
SW100 - CD with free PC program
LP002 - COM adapter for communication with personal computer via RS232 serial port
LP003 - USB adapter for communication with personal computer via USB port
LP005 - LAN adapter for communication with the PC via Ethernet, including ac/dc adapter 230Vac/5Vdc.
Exceeding of adjusted limits is alarmed by sending e-mail message or trap.
Accessories for
communication with loggers via GSM - see further LP004 - start/stop magnet
MD036 - self adhesive Dual Lock for easy installation
A4203 - spare Lithium battery 3.6V, no leads, size AA
for S3631 it is necessary to order probe with Pt1000 sensor with K1321 connector - symbol /E behind probe name
K0921 - watertight female connector Canon 9 pins for connection of 0-5V signals of S3541 logger, protection IP67
K0925 - female connector Canon 9 pins for connection of input signals of S3541 logger, protection IP20
K0945 - adapter with terminals for easy connection of 0-5V signals of S3541, protection IP20







RELATIVE HUMIDITY AND
F5200 - grey sensor cover with filter from stainless steel mesh, filtering ability 0,025mm
F5200B - black sensor cover with filter from stainless steel mesh, filtering ability 0,025mm for S3121, R3121 loggers
F9000 - wall holder with lock
SWR004 - optional software for Windows color print, vertical and time zooming of graphs and other functions
SWR007 - program package Database Logger Program for work with data from Comet loggers. Program enables i.a.:
- To set locally the GSM modem via RS232 link by means of QMS2901 cable.
- To view selected channels from any Comet logger together with selected channels of other Comet loggers.
- Measurement from different Comet devices is possible to combine in one table or graph.
- To choose any time interval for analysis print or export to PDF - table and graph - see also page 23.
LP004 - start/stop magnet F9000 - wall holder with lock Thermometer hygrometer S3121 K0921- watertight co n Sensor cover with filter from for input signals of S3541 LP005 - LAN adapter stainless steel mesh Accessory for humidity adjustment and calibration by the user:
MD046 - vessel for humidity calibration and adjustment
HM023 - set of 5 humidity standards 10% RH with 5 application pads
HM024 - set of 5 humidity standards 80% RH with 5 application pads

Source: http://www.acandia.se/pub_docs/files/Datalogger/logger-humidity_comet_2010-08-19.pdf

program litteraturfestivalen 2007-2

SIGRID UNDSET DAGENE DEN NORSKE LITTERÆRE KANON FORFATTERE VELGER FILM NORDISKE POETER SKANDINAVISKEMØTER KRIM I PARKEN LUNSJ I PARKEN OPPLYSNINGSTID LITTERATURKIOSKEN TEGNESERIE-VERKSTED OVERSETTERTIMEN FORFATTERNES HUS HAGEFEST STEREO PÅFYLL UNGTEKST 2 PÅ1 TIME FIRE FORFATTERE OG ET BAND SKOTSK MALTWHISKY SKRIVEKURS KONSERTER TEATERKUNSTUTSTILLINGER ELVEVANDRING PUB TIL PUB BANKNATTA

200913660 8605.8610

Phenothiazines inhibit S100A4 function by inducing protein oligomerizationVladimir N. Malashkevicha, Natalya G. Dulyaninovaa, Udupi A. Ramagopala, Melissa A. Lirianob, Kristen M. Varneyb,David Knighta2, Michael Brenowitza, David J. Weberb, Steven C. Almoa, and Anne R. Bresnicka,1 aDepartment of Biochemistry, Albert Einstein College of Medicine, 1300 Morris Park Avenue, Bronx, NY 10461; and bDepartment of Biochemistry and